Power contactor options, Class 8998 motor control centers, Only one option is allowed – Schneider Electric ALTIVAR 58 TRX User Manual

Page 217

Advertising
background image

Class 8998 Motor Control Centers

Power Contactor Options

217

09/2003

©

2000–2003 Schneider Electric All Rights Reserved

POWER CONTACTOR OPTIONS

Only one option is allowed.

Power Circuit
Diagram

Nominal Motor Horsepower (hp)
and Type of Torque

Integrated Bypass
Only Available with
Circuit Breaker
Disconnect; Uses
Telemecanique
Contactors.

Barriered Bypass
Uses NEMA
Contactors

Barriered
Application Rated

COMPAC™ 6 Bypass
(14 A max.)

Load Contactor

Line Contactor

208 Vac

240 Vac

480 Vac

Additional Space

Additional Space

Additional Space

Additional Space

Additional Space

1-5 All

0.5-10 All

12"

18"

6"

12"

12"

5-10 All

15-20 All
and
25 hp VT

12"

18"

Not available

12"

12"

15-25 VT
15-20 CT

15-20 VTLN

30-50 VT
25-40 CT
25-40 VTLN

9"

27"

Not available

9"

9"

30-50 VT
25-40 CT

25-40 VTLN

60-100 VT
50-75 CT
50-75 VTLN

5" added to width

33" in adjacent section for
circuit breaker; 39" in
adjacent section for FS

Not available

5" added to width

5" added to width

50 VT

5" added to width

25" added to width

Not available

5" added to width

5" added to width

125-200 VT
100-200 CT

20" added to width

25" added to width

Not available

Consult factory.

Consult factory.

• Basic Drive features with

isolation and bypass
contactors for emergency
full speed operation in
same compartment.

• Telemecanique D or

F line contactors are
used.

• Only available as Circuit

Breaker disconnect
common to drive and
bypass.

• Drive and bypass are UL

845 Listed for 100,000 A
Short Circuit Current and
coordinated for Type 1
protection.

• Includes AFC-Off-

Bypass selector switch,
Red Push-To-Test “AFC”
Pilot Light and Yellow
Push-To-Test “Bypass”
Pilot Light on bypass
control island.

NOTE: Bypass is not
isolated from the drive
compartment. Both drive
and bypass must be
removed at the same time.

• Basic Drive features with isolation and bypass

contactors for emergency full speed operation.

• Barriered Application Rated COMPAC 6 Bypass uses

Telemecanique contactors. NEMA contactors are used
on barriered NEMA bypass.

• Separate disconnect for drive and bypass can be

operated independently.

• Drive and bypass starter are enclosed in separate

barriered compartments.

• Drive and bypass are UL 845 Listed for 100,000 A Short

Circuit Current and coordinated for Type 1 protection.

• Includes AFC-Off-Bypass selector switch,

Red Push-To-Test “AFC” Pilot Light and Yellow Push-
To-Test “Bypass” Pilot Light on bypass control island.
(Non-Push-To-Test used on COMPAC 6)

• Basic Drive features with

load contactor for motor
isolation. Contactor is
open when drive is not
running.

• Telemecanique D or F

line contactors are used.

• Drive and load contactor

are UL 845 Listed for
100,000 A Short Circuit
Current.

• Basic Drive features with

line contactor for isolating
drive from input line.

• Telemecanique D or F

line contactors are used.

• Drive and line contactor

are UL 845 Listed for
100,000 A Short Circuit
Current.

Abbreviations for type of torque are as follows: VT = Variable Torque; CT = Constant Torque; VTLN = Variable Torque, Low Noise.

M

CB

Power

Fuse

Drive

8998-004.ar

t

M

CB

CB

or

Disc

or

Disc

Power

Fuse

Drive

Separate

Bypass

Unit

8998-005.ar

t

M

CB

or

Disc

Power

Fuse

Drive

8998-006.ar

t

M

CB

or

Disc

Power

Fuse

Drive

8998-007.ar

t