Multi-drive process line cabinets, Class 8998 motor control centers – Schneider Electric ALTIVAR 58 TRX User Manual

Page 220

Advertising
background image

Class 8998 Motor Control Centers

Multi-Drive Process Line Cabinets

220

09/2003

©

2000–2003 Schneider Electric All Rights Reserved

MULTI-DRIVE PROCESS LINE CABINETS

MCC-style 90" high relay sections are available with group-mounted Altivar 58 TRX AC drives. All drives
are installed together in one cabinet instead of individual plug-on MCC units. This allows greater density
and reduces floor space over traditional MCC unit construction. Drives are not isolated from each other,
and are fed from one circuit breaker disconnect.

Multi-drive process line cabinets are suited for process line applications where a fault or maintenance
of one drive on the process requires the entire process to shut down. Applications in automotive, food
and beverage, pharmaceutical, and other process industries using multiple drives for a single process
machine are candidates for this product. Pre-engineered, pre-assembled packaging saves third-party
assembly labor and commission time on simple installations.

An efficient cooling system and current-limiting fuses provide factory-assured, UL-certified performance
to UL 845 MCC standards. Each drive has a uniquely numbered door-mounted keypad for easy
monitoring and setup. Drives can be set up with a program from a single keypad if preferred.

Only drives rated 480 Vac are available and are pre-programmed for constant torque applications. No
control pilot devices or 120 Vac control power is available, making this package more suited for simple
remote control schemes or for further integration in the field. Packages are designed for NEMA Type 1
environments. Horizontal bus is provided for splicing to existing Model 5 or 6 MCC sections or an
additional MCC incoming line section.

Any number of drives up to the maximum indicated in the table below may be installed in the multi-drive
process line cabinet. However, all drives in the same cabinet must be of the same rating. Panels for
adding the maximum number of drives will be installed.

Consists of MCC relay section with multiple drives of the same rating fed from a single circuit breaker
disconnect.

Current-limiting power fuses are included for each drive. Power fuses are UL Class CC or T.

Package is UL 845 Listed for 65,000 A short circuit current.

Keypad displays for each drive are mounted on the door of the cabinet.

No pilot devices are available as standard.

Control power transformer (480 /240 Vac) for cabinet ventilation fans is included.

Any number of drives from one to the maximum indicated can be factory installed.

Drives must be of the same rating in a single cabinet.

Motor-Rated
Horsepower at
460 Vac

Type of
Torque

Maximum Continuous
Output Current (A)

Maximum Number of
Drives per Section

Space Adder

1

All types

2.3

10

72" (25" wide x 20" deep)

2

All types

4.1

3

All types

5.8

5

All types

10

8

7.5

All types

13

10

All types

17

6

72" (30" wide x 20" deep)

15

All types

24

20

All types

33

4

25

Variable Torque

34

2

Constant Torque

40

30

Variable Torque

40

Constant Torque

48

40

Variable Torque

52

Constant Torque

66

50

Variable Torque

65

m

u

lti10d_49%

m

ulti10_34%

M

M

M

M

CB

N

Times

8998-008.ar

t

Advertising
This manual is related to the following products: