Summary of user interface options, I/o extension cards, Overview of i/o extension cards – Schneider Electric ALTIVAR 58 TRX User Manual

Page 26: Altivar, 58 trx ac drives

Advertising
background image

Altivar

®

58 TRX AC Drives

Summary of User Interface Options and I/O Extension Cards

©

2000–2003 Schneider Electric All Rights Reserved

26

09/2003

SUMMARY OF USER INTERFACE OPTIONS

The following table lists the various user interface options and provides a catalog number for ordering.

I/O EXTENSION CARDS

Overview of I/O Extension Cards

The ATV58 TRX controller can be specially adapted for certain applications by installing an I/O
extension card. One I/O extension card can be mounted into the ATV58 TRX drive controller. Space is
already provided in the controller for the card; no retrofitting or additional panel space is required. Three
models are available:

• I/O Extension Card with Analog Input (VW3A58201U).

• I/O Extension Card with Encoder Inputs (VW3A58202U).

• Pump Switching Option Card (VW3A58210U).

If these I/O extension cards do not meet your needs, Schneider Electric can design and supply
customer-specific I/O extension cards, incorporating both hardware functions (I/O) and software
functions.

A 115 Vac logic input module (VW3A58275U) is available for applications requiring 115 Vac control
circuits.

The following sections describe the I/O options in greater detail.

User Interface Option

Description

Catalog Number

Keypad Display

This plug-in terminal is inserted into a slot on the front panel of the ATV58 TRX controller.

VW3A58101U

Kit for Remote Location of
Keypad Display

This kit may be used to locate the keypad display remotely (for example, on the door of the
enclosure). The kit includes a 3-meter (9.8 foot) cable with connectors; a translucent protective
cover for the keypad; and seals and screws for IP65 mounting on an enclosure door.

VW3A58103

PowerSuite Software

PowerSuite commissioning software on CD

VW3A8104

PC Connection Kit

Includes the following to connect a PC to an ATV11, ATV28, ATV58, or ATS48 controller:
• 1 m cable with RJ45 connectors
• RS-232 to RS-485 adapter with RJ45 and DB9 female connectors
• RJ45 to DB9 adapter for use with an ATV58 controller
• Cable adapter for use with an ATV11 controller, VW3A11301

VW3A8106

PPC Connection Kit

Includes the following to connect a Jornada or iPAQ PPC to an ATV11, ATV28, ATV58, or ATS48
controller:
• 1/2 m cable with RJ45 connectors
• RS-232 to RS-485 adapter with RJ45 and DB9 female connectors
• RJ45 to DB9 adapter for use with an ATV58 controller
• Cable adapter for use with an ATV11 controller, VW3A11301

VW3A8111

RS-485 Connection Kit

This kit allows RS-485 multidrop serial link connection to PLCs, man-machine terminals. It is
connected in place of the keypad display, and therefore prevents the use of the keypad display
at the same time that the ATV58 TRX controller is connected to PLCs. The kit includes a 3-meter
(9.8 foot) cable with one male 9-pin SUB-D connector and one male 15-pin SUB-D connector;
and a manual.

VW3A58306U

Magelis Terminal

This option is used with RS-485 connection kit. A cable, XBT2908 is included in the kit.

XBTHM017010A8