Section 4 Heater Controller Operation

Temperature Control

(3) Temperature Control Stop Condition

Function:

To prevent useless current consumption, to protect
the paper from being damaged due to the heating
of heaters, and to protect the user from getting
burned due to a touch to the heaters when print is
not performed.

Status:

Status of reaching the environmental temperature
slowly.

Condition:

In case of conditions other than preset
temperature maintaining condition and standby
temperature maintaining condition.

Start of heating

End of heating

Start of print

End of print

Print heater preset temperature

Rear heater preset temperature

Front heater preset temperature

Standby temperature

Environmental temperature

Keeping of the

preset temperature

Keeping of the

stand by temperature

Keeping of the

preset temperature

Keeping of the

stand by temperature

Stop of the

temperature control

Print

Print

Delay

time

setting

value

Delay

time

setting

value

Standby setting

time

Standby setting

time

(Time)

(Temperature)

Start of heating: The print start command is received and the

heating starts. (The print operation does not
start until the heaters reach the preset tempera-
ture. However, if "WAIT HEATER" is set to
"SKIP", the print operation starts even though
the heaters do not reach the preset temperature.)

Start of print:

The heaters reached the preset temperature and

the print operation starts.

End of print:

The print end command is received and the

print operation finishes.