4-6

Parameter Setup Mode

This mode is used when the operator sets the heater control system
parameters.

(1) Setup items and parameters

The setup items and parameters are listed in the table below.

*1 Display only, ON/OFF key is ignored.

(2) Entering the parameter setup mode

Press the ON/OFF key,

key, and

key on the heater control

panel at the same time to enter to the parameter setup mode.
The 1st setup item in the parameter setup mode will be displayed.

Note: # will be blinked.

No.

Item

Item Display

(upper line)

Parameters

Display

(lower line)

Description

Initial value

1

Temperature unit

UNIT

CELSIUS
FAHRENHEIT

-

CELSIUS

2

Heat suspending
time after printing

DELAY TIME

00 to 30 MINUTE

UNIT: minute

05 MINUTES

3

Standby heating

time after
completion of
DELAY TIME

STANDBY TIME

0, 30, 60, 90, 120,
ENDLESS

Unit: minutes

30

4

Version display

VERSION

FW=vv.r HW=vv.r Display only

-

5

Diagnostics

DIAGNOSTICS

NO, YES

NO: Does not perform

the diagnostics.

YES: Performs the

diagnostics.

NO

6

Display language

LANGUAGE

ENGLISH
JAPANESE

-

ENGLISH

7

Exit of setup mode EXIT

YES, NO

YES: Exits from the

parameter mode.

NO: Does not exit from

the parameter mode.

YES

# UNIT

* CELSIUS