Section 4 Heater Controller Operation

(8) Preheat by manual operation

The front heater, print heater, and rear heater start to heat until they
reach the set temperature by pressing simultaneously respective
ON/OFF buttons on the heater panel.

NOTE

Simultaneous pressing

Turning on respective heaters in prior to the print can shorten the
heater temperature rise waiting time at the start of printing.

- After the heating started by manual operation, the heaters

turn off automatically through the delay time and standby

time set by the parameters.

- During the printing, these buttons function as normal ON/

OFF buttons.