Sun Fire V490 Server Administration Guide • August 2004

In addition to that information, prtdiag with the verbose option (-v) also reports
on front panel status, disk status, fan status, power supplies, hardware revisions,
and system temperatures.

CODE EXAMPLE 6-9

prtdiag

Verbose Output

In the event of an overtemperature condition, prtdiag reports an error in the Status
column.

CODE EXAMPLE 6-10

prtdiag

Overtemperature Indication Output

Similarly, if there is a failure of a particular component, prtdiag reports a fault in
the appropriate Status column.

CODE EXAMPLE 6-11

prtdiag

Fault Indication Output

prtfru

Command

The Sun Fire V490 system maintains a hierarchical list of all field-replaceable units
(FRUs) in the system, as well as specific information about various FRUs.

System Temperatures (Celsius):

-------------------------------

Device

Temperature

Status

---------------------------------------

CPU0 59 OK

CPU2 64 OK

DBP0 22 OK

System Temperatures (Celsius):

-------------------------------

Device

Temperature

Status

---------------------------------------

CPU0

62

OK

CPU1

102

ERROR

Fan Status:

-----------

Bank RPM Status

---- ----- ------

CPU0 4166 [NO_FAULT]

CPU1 0000 [FAULT]