Reference for terms in diagnostic output, Table 6-13 – Sun Microsystems Sun Fire V490 User Manual

Page 142

Advertising
background image

114

Sun Fire V490 Server Administration Guide • August 2004

Reference for Terms in Diagnostic
Output

The status and error messages displayed by POST diagnostics and OpenBoot
Diagnostics tests occasionally include acronyms or abbreviations for hardware sub-
components.

TABLE 6-13

is included to assist you in decoding this terminology and

associating the terms with specific FRUs, where appropriate.

TABLE 6-13

Abbreviations or Acronyms in Diagnostic Output

Term

Description

Associated FRU(s)

ADC

Analog-to-Digital Converter

PCI riser board

APC

Advanced Power Control – A function provided
by the SuperIO integrated circuit

PCI riser board

BBC

Boot Bus Controller – Interface between the
processors and components on many other buses

Centerplane

CDX

Data Crossbar – Part of the system bus

Centerplane

CRC

Cyclic Redundancy Check

N/A

DAR

Address Repeater – Part of the system bus

Centerplane

DCDS

Dual Data Switch – Part of the system bus

CPU/Memory board

DMA

Direct Memory Access – In diagnostic output,
usually refers to a controller on a PCI card

PCI card

EBus

A byte-wide bus for low-speed devices

Centerplane, PCI riser
board

HBA

Host Bus Adapter

Centerplane, various
others

I

2

C

Inter-Integrated Circuit (also written as I2C) – A
bidirectional, two-wire serial data bus. Used
mainly for environmental monitoring and control

Various. See

TABLE 6-12

.

I/O Board

PCI Riser

PCI riser

JTAG

Joint Test Access Group – An IEEE subcommittee
standard (1149.1) for scanning system components

N/A

MAC

Media Access Controller – Hardware address of a
device connected to a network

Centerplane

MII

Media Independent Interface – Part of Ethernet
controller

Centerplane

Motherboard

Centerplane

Centerplane

Advertising