Diagnostic Tools

97

The prtfru command can display this hierarchical list, as well as data contained in
the serial electrically-erasable programmable read-only memory (SEEPROM) devices
located on many FRUs.

CODE EXAMPLE 6-12

shows an excerpt of a hierarchical list of

FRUs generated by the prtfru command with the -l option.

CODE EXAMPLE 6-12

prtfru -l

Command Output

CODE EXAMPLE 6-13

shows an excerpt of SEEPROM data generated by the prtfru

command with the -c option.

CODE EXAMPLE 6-13

prtfru -c

Command Output

Data displayed by the prtfru command varies depending on the type of FRU. In
general, this information includes:

FRU description

Manufacturer name and location

Part number and serial number

Hardware revision levels

Information about the following Sun Fire V490 FRUs is displayed by the prtfru
command:

Centerplane

CPU/Memory boards

DIMMs

FC-AL disk backplane

FC-AL disk drive

PCI riser

/frutree

/frutree/chassis (fru)

/frutree/chassis/io-board (container)

/frutree/chassis/rsc-board (container)

/frutree/chassis/fcal-backplane-slot

/frutree/chassis/rsc-board (container)

SEGMENT: SD

/ManR

/ManR/UNIX_Timestamp32: Fri Apr 27 00:12:36 EDT 2001

/ManR/Fru_Description: SC PLAN B

/ManR/Manufacture_Loc: BENCHMARK,HUNTSVILLE,ALABAMA,USA

/ManR/Sun_Part_No: 5015856

/ManR/Sun_Serial_No: 001927

/ManR/Vendor_Name: AVEX Electronics

/ManR/Initial_HW_Dash_Level: 02

/ManR/Initial_HW_Rev_Level: 50

/ManR/Fru_Shortname: SC