System Specifications

219

Environmental Specifications

The operating and non-operating environmental specifications for the system are
as follows.

Parameter

Value

Operating

Temperature

5˚ C to 35˚C (41˚F to 95˚F)—IEC 60068-2-1&2

Humidity

20% to 80% RH noncondensing; 27˚C (81˚F) wet bulb—
IEC 60068-2-3&56

Altitude

0 to 3000 meters (0 to 10,000 feet)—IEC 60068-2-13

Vibration

.0001 (z-axis only) G

2

/Hz, 5-150 Hz, -12db/octave slope,

150-500 Hz— IEC 60068-2-13

Shock

3g peak, 11 milliseconds half-sine pulse—IEC 60068-2-27

Declared Acoustics

72 DbA

Non-Operating

Temperature

-20˚C to 60˚C (-4˚F to 140˚F)—IEC 60068-2-1&2

Humidity

95% RH noncondensing—IEC 60068-2-3&56

Altitude

0 to 12,000 meters (0 to 40,000 feet)—IEC 60068-2-13

Vibration

.001 (z-axis only) G

2

/Hz, 5-150 Hz, -12db/octave slope,

150-500 Hz— IEC 60068-2-13

Shock

10g peak, 11 milliseconds half-sine pulse—IEC 60068-2-27

Handling Drops

25 mm (10 in)

Threshold Impact

1 meter/second