Simrad EQ60 User Manual

Page 101

Advertising
background image

Instruction manual

89

857-164342 / Rev.C

Serial Line - Heave sensors with a serial line output are
connected to a RS-232 port at the rear of the echo sounder’s
processor unit.

Protocol - These options are only available when Serial Line
has been chosen. Use these to select serial line input format. The
echo sounder recognises one character based telegram
(Sounder/TSS1) and two binary telegrams (EM 1000 and EM
3000).

Data Input

The most recent input data is displayed in a list. With analogue
input the input voltage and the computed heave value are
displayed. With serial line input the telegram content is
displayed. This function is useful during installation and trouble
shooting. The current heave value is displayed in meters in the
lower left corner of the dialogue box.

Clear - This button clears the input data list.

Depth Output

This opens the Depth Output dialogue box.

RS-232

This button activates the RS-232 Setup dialogue box. This box
is used to define communication port, baud rate etc.

Related topics

Depth Output, page 80

RS-232 Setup, page 107