Single frequency, split beam transducer, Special transducer cable is available from simrad – Simrad EQ60 User Manual

Page 170

Advertising
background image

Simrad EQ60

158

857-164342 / Rev.C

Split beam transducer connected as single beam

The drawing shows how to connect a split beam transducer to a
single beam system.

W802-5 / Rev.C

Split beam transducer connected as single beam

Single frequency, split beam
transducer

C
D

GPT

Junction Box (1:1)

Ch.1

Ch.3

Ch.2

Forward

Aft

Starboard

Port

Ch.4

Blue

Blue

Blue

Blue

Black

Black

Black

Black

M

E

F

J

H

D

C

K

L

A

B

N

Inner
screen

Outer

screen

Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must

be connected to

ship's ground in the junction box.

not

Plug housing

Ch.4

Ch.3

Ch.2

Ch.1

Conductors

4 x 2 x N mm2

Screen

Overall braided

Voltage

600 V

Max.diameter

N/A

The conductor diameter “N” depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm

2

. Special

transducer cable is available from Simrad.