Basic operations

Overview

This chapter presents a number of common procedures
frequently carried out on the EQ60 echo sounder.

Changing the echogram settings

To change the echogram settings:

1

Position the cursor in the Echogram field.

2

Click the right mouse button.

3

Observe the

Echogram

dialogue box.

4

Make the required changes.

Related topics

Echogram, page 81

Changing the range

To change the range:

1

Position the cursor in the Range field.

2

Click the right mouse button.

3

Observe the

Bottom Range

or

Surface Range

dialogue

box.

4

Make the required changes

or:

1

Place the cursor in the Range field.

2

Use the mouse wheel to change the range.

Related topics

Bottom Range, page 77

Surface Range, page 110

Changing the vertical resolution

The vertical resolution of the echogram increases with a shorter
pulse length.

For example, a pulse length of 1.024 millisecond gives a vertical
resolution of 19.2 cm, whereas a pulse length of 0.256
millisecond gives a vertical resolution of 4.8 cm. If the vertical
distance between two echoes is less than this, the two echoes
will be shown as one