Simrad EQ60 User Manual

Page 201

Advertising
background image

Transducer installation

189

857-164342 / Rev.C

The tube should be unbroken and watertight from the transducer
to above the water line. From there, openings or a junction box
can be installed to facilitate drawing of the cable, or to add a
cable extension. However, the tube should act as a continuous
electrical screen all the way and be connected to the transceiver
chassis.

Tube dimensions:

• minimum 35 mm inner diameter
• minimum 6 mm wall thickness (4.5 mm if galvanised).

If two or more transducers are installed close to each other it is
possible to pull their cables in the same steel tube, provided the
tube diameter is increased accordingly. However, for easy
replacement it is recommended that each transducer has its own
steel tube.

Most Simrad transducers are delivered with 20 m cable. Excess
cable can be cut off, or an extension cable can be added. This is
possible because all Simrad transducers have a built-in
transformer for tuning and matching to the cable impedance of
75 Ohms.

Advertising