Single frequency, dual beam

The drawing shows how to connect a single frequency, dual
beam transducer to the system.

Note

Check the transmit power if wide beam is selected in order not
to exceed the power capacity on the transducer.

M

E

F

J

H

D

C

K

L

A

B

N

W802-2 / Rev B

Single frequency, dual beam

Single frequency,
dual beam transducer,
wide

Single frequency,
dual beam transducer,
narrow

C

C

D

D

GPT

GPT

Inner
screen

Inner
screen

Outer

screen

Outer

screen

Junction Box (1:1)

Junction Box (1:1)

Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must

be connected to

ship's ground in the junction box.

not

Plug housing

Plug housing

Conductors

3 x N mm2 or 2 x N mm2

Screen

Overall braided

Voltage

600 V

Max.diameter

N/A

The conductor diameter “N” depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm

2

. Special

transducer cable is available from Simrad.