10 - 40 DS6707 Digital Imager Scanner Product Reference Guide

CLSI Editing

Parameter # 36h

When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and
tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data
format.

NOTIS Editing

Parameter # 37h

When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enable
this feature if the host system requires this data format.

NOTE

Symbol length does not include start and stop characters.