4 - 10 DS6707 Digital Imager Scanner Product Reference Guide

Decode Session Timeout

Parameter # 88h

This parameter sets the maximum time decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.

To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from

Appendix

D, Numeric Bar Codes

that correspond to the desired on time. Single digit numbers must have a leading zero.

For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and
5 bar codes. To correct an error or change the selection, scan Cancel on

page D-2

.

Timeout Between Decodes, Same Symbol

Parameter # 89h

This option is used in hands-free (Intellistand) mode to prevent the beeper from continuously beeping when a
symbol is left in the digital imager scanner’s field of view. It is programmable in 0.1 second increments from 0.0
to 9.9 seconds. The default interval is 0.6 seconds.

To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric
bar codes from

Appendix D, Numeric Bar Codes

that correspond to the desired interval, in 0.1 second

increments.

Decode Session Timeout