Kodak 9090DC User Manual

Page 60

Advertising
background image

6-8

A-61662 October 2011

4. With the imaging guide still out of the scanner, locate the glass

camera cover between and below the LED lamps.

5. Using a clean dry swab, gently wipe across the glass camera cover

to remove any dirt and dust particles. Do not spray any solvent on
the swab unless a dry swab will not remove the residue on the
glass. If you need to use solvent, spray the solvent on the swab. Do
not spray solvent in or around the internal components of the
scanner.

6. When the camera cover is clean, re-insert the cleaned imaging

guide into the scanner by holding the frame of the imaging guide so
that the fastening clips are on the back side of the imaging guide.
Slide the guides under the transport tray towards the feeder table
and ease the back side of the imaging guide into position.

7. Repeat Steps 2 - 6 to clean the bottom imaging guide and bottom

camera cover.

8. When finished, close the scanner cover.

Imaging guide removed

Camera cover

LEDs

Lamp


Imaging

Five guides slide underneath the transport tray

Fastening clips

guide

Advertising