Replacing the pre-separation pad, Replacing the imaging guides, Lamps (leds) – Kodak 9090DC User Manual

Page 65

Advertising
background image

A-61662 October 2011

6-13

Replacing the pre-
separation pad

Change the pre-separation pad when the frequency of multi-fed
documents increases.

1. Open the scanner cover.

2. Remove the pre-separation pad by lifting the pad up and out of

position.

NOTE: The pre-separation pad fits snuggly in place; therefore, a

little force may be required to remove it.

3. Install the new pre-separation pad. Be sure it snaps into place.

4. Close the scanner cover.

Replacing the imaging
guides

Replace the imaging guides when they become damaged or heavily
scratched. See the section entitled, “Cleaning the optics” earlier in this
chapter for detailed procedures about removing the imaging guides.

1. Open the scanner cover.

2. Gently pull the 2 fastening clips that secure the top imaging guide

towards the front of the scanner to release and remove the imaging
guide from the transport.

3. Install the new imaging guide into the scanner by holding the frame

of the imaging guide so that the fastening clips are on the back side.
Slide the guides under the transport tray towards the feeder table
and ease the back side of the imaging guide into position.

4. Repeat Steps 2 and 3 to replace the bottom imaging guide.

5. Close the scanner cover.

Lamps (LEDs)

IMPORTANT: The LEDs on Ngenuity scanners should NOT be cleaned

or wiped with any type of wipes and/or solvent.

The LED illumination system on Ngenuity Scanners should last the life
of the scanner with normal use. If something happens that requires the
replacement of the LEDs, contact Kodak Technical Support.

Advertising