Operation – Lincoln Electric POWER FEED IM892-C User Manual

Page 19

Advertising
background image

B-3

OPERATION

B-3

RECOMMENDED PROCESSES

• GMAW (CV, Synergic CV, Pulse, STT™, Power,

Pulse on Pulse™, Push-Pull)

• FCAW

• SMAW

• GTAW (Lift Start only)

• Solid wires .025" to 1/16"

• Cored wires .035" to 5/64"

• Cored wires .035" to 3/32" when configured for

"extra torque"

EQUIPMENT LIMITATIONS

• Works only on ArcLink

®

or LincNet Power Wave

power sources.

• When operating on LincNet power sources, not all

features are available.

• Maximum gun length is 25ft.(7.6m) for push-only

systems.

• Maximum gun length is 50ft.(15.2m) for push-pull

systems.

• Spool guns do not work with the POWER FEED™

25M.

• A remote control/foot amptrol and a push-pull gun

may not be connected to the POWER FEED™ 25M

simultaneously.

• Maximum spool size is 12 in. (305 mm) diameter

• Maximum spool weight is 44 lb (20 kg).

• Maximum control cable length is 200 ft (61 m).

• Other gun bushings are required for welding guns

that do not have a Magnum (Tweco #2-#4 compati-

ble) back end.

• No more than 2 wire feeders may be connected to

one ArcLink power source at a time.

RECOMMENDED POWER SOURCES

• Power Wave

®

355M

• Power Wave

®

455M

• Power Wave

®

455M/STT

• Power Wave

®

655/R

POWER FEED™ 25M