Operation – Lincoln Electric POWER FEED IM892-C User Manual

Page 58

Advertising
background image

B-42

OPERATION

B-42

POWER FEED™ 25M

2 STEP - 4 STEP - TRIGGER OPERATION

(For Code 11313)

The 2 Step - 4 Step

switch changes

the function of the gun trigger. 2 Step

trigger operation switches the welding

output ON-OFF in direct response to

the trigger. 4 Step trigger operation

provides 'trigger interlock' capability

and gives the ability to control the

amount of time spent in the arc start

and arc crater steps.

Place the toggle switch in the UP posi-

tion for 4 Step operation and in the

DOWN position for 2 Step operation.

The 2 Step - 4 Step trigger has no effect when weld-

ing with SMAW or CAG procedures.

2 Step Trigger

2 Step trigger operation is the most common. When

the gun trigger is pulled, the welding system (power

source and wire feeder) cycles through the arc start-

ing sequence and into the main welding parameters.

The welding system will continue to weld as long as

the gun trigger is activated. Once the trigger is

released, the welding system cycles through the arc

ending steps.

4 Step Trigger

4 Step trigger operation gives the welder additional

control in the welding sequence. 4 step trigger allows

the welder to choose the arc start, weld and arc end

time. It may also be set-up to work as a trigger inter-

lock.

2-STEP

4 STEP

2- STEP 4- STEP- TRIGGER OPERATION

Code 11456 and higher:

The 2-Step - 4-Step switch changes the function of

the gun trigger. 2-Step trigger operation switches the

welding output ON-OFF in direct response to the trig-

ger. 4-Step trigger operation provides 'trigger interlock'

capability and gives the ability to control the amount of

time spent in the arc start and arc crater steps.

Press the push button on the case front to toggle

between 2-Step and 4-Step operation.

The 2-Step, 4-Step trigger has no effect when weld-

ing with SMAW or CAG procedures.

2-Step Trigger

2-Step trigger operation is the most common. When

the gun trigger is pulled, the welding system (power

source and wire feeder) cycles through the arc start-

ing sequence and into the main welding parameters.

The welding system will continue to weld as long as

the gun trigger is activated. Once the trigger is

released, the welding system cycles through the arc

ending steps

4-Step Trigger

4-Step trigger operation gives the welder additional

control in the welding sequence. 4-Step trigger allows

the welder to choose the arc start, weld and arc end

time. It may also be set-up to work as a trigger inter-

lock.