Operation, B-33 – Lincoln Electric POWER FEED IM892-C User Manual

Page 49

Advertising
background image

B-33

OPERATION

B-33

POWER FEED™ 25M

USER MEMORIES

Recall a memory with memory buttons

To recall a user a memory, press one of the six user

memory buttons. The memory is recalled when the

button is released. Do not hold the button for more

than two seconds when recalling a user memory.

Recall a memory with the gun trigger

If desired, memories 2 through 6 can be recalled with

the gun trigger. For example, to recall memory 3,

quickly pull and release the gun trigger 3 times without

welding.

Note: the POWER FEED™ Wire Feeders are factory

set with this feature disabled. Use the SETUP menu

and change P.4 to enable memory recall with the gun

trigger.

Save a memory with memory buttons

To save a memory, press and hold the desired memo-

ry button for two seconds. When the button is initially

pressed, the corresponding LED will illuminate. After

two seconds, the LED will turn off. Do not hold the

button for more than 5 seconds when saving a user

memory.

Note: that memories may be locked using Weld

Manager from a P.C. or Palm application to prevent

accidental overwrite of the memories. If an attempt is

made to save a memory when memory saving is

locked, the message "Memory save is Disabled!" will

appear briefly in the MSP4 display.

HOLD 2 SECONDS TO SAVE

PROCEDURE

MEMORY

A

GUN

B

1

4

2

5

3

6

M

M

PROCEDURE/MEMORY PANEL OPERA-

TION

(For Code 11313):

The Dual Procedure/Memory Panel performs three

functions:

• Weld procedure selection

• Memory save and recall

• Limits setting

There are two procedure memories (A and B) and six

user memories (1-6).

Procedure Memory vs. User Memory

Procedure memory is used while welding. Changes to

the weld procedure (WFS, voltage, arc control, etc.)

immediately change the contents inside the selected

procedure memory.

User memories work by copying the weld procedure

from one of the six memories into either the A or B

procedure. Weld procedures are saved into the mem-

ories only when the operator chooses.

Using Procedure Memories

Procedure memories can be selected by choosing

either "A" or "B" procedure directly with the memory

panel, or by selecting "GUN" and using a dual proce-

dure gun to select between procedure "A" and "B".

When selecting procedures with the gun switch, "A" or

"B" will flash to show which procedure is active.

HOLD 2 SECONDS TO SAVE

PROCEDURE

MEMORY

A

GUN

B

1

4

2

5

3

6

M

M

HOLD 2 SECONDS TO SAVE

PROCEDURE

MEMORY

A

GUN

B

1

4

2

5

3

6

M

M

RECALL

PRESS 1

SECOND

SAVE

PRESS 2

SECONDS

PROCEDURE

MEMORY

PRESS TO

SELECT

PROCEDURE OR

QUICK TRIGGER-

WHILE

WELDING

USER

MEMORIES

Advertising