Operation – Lincoln Electric POWER FEED IM892-C User Manual

Page 38

Advertising
background image

B-22

OPERATION

B-22

PEAK CURRENT

(Figure B.16)

Peak current controls the arc length, which also

affects the shape of the root. When using 100% CO

2

,

the peak current will be higher than when welding with

blended shielded gases. A longer arc length is

required with CO

2

to reduce spatter.

FIGURE B.16

BACKGROUND CURRENT

(Figure B.17)

Background current adjusts the overall heat input into

the weld. Changing the background current changes

the shape of the back bead. 100% CO

2

requires less

background current than when welding with blended

shielding gases.

FIGURE B.17

TAILOUT

Tailout provides additional heat into the weld without

increasing the arc length or the droplet size. Higher

tailout values improve wetting and may give faster

travel speeds.

POWER FEED™ 25M

Peak

Current

Too Low

Peak

Current

Optimum

Peak

Current

Too High

Background

Current

Too Low

Background

Current

Optimum

Background

Current

Too High