Operation, B-38 – Lincoln Electric POWER FEED IM892-C User Manual

Page 54

Advertising
background image

B-38

OPERATION

B-38

POWER FEED™ 25M

If the passcode does not equal zero (0000), enter the

passcode now. If the passcode has been forgotten, a

p.c. computer application or Palm O.S. application is

required to change the passcode

If the passcode has been set to zero (0000), SETUP will

illuminate on the MSP4 panel and the display will show

the following:

Four items show on the MSP4 panel.

• Memory Value

• High Limit

• Low Limit

• Parameter Name

One of these items will flash to indicate which item will

change when the MSP4 encoder is rotated. Press the

right button on the MSP4 panel to select the item to

change.

The Limits Setup menu shows a list of all parameters

available for the weld mode stored in the memory

chosen. For example, if limits are being set for a stick

(SMAW) mode, parameters such as Run-in WFS and

Postflow will not appear.

To lock a parameter to a specific value that can-

not be changed, set the high and low limits to the

same value.

WELD WFS

HI = 200 LO = 180

WELD MODE
ARC CONTROL

START OPTIONS
END OPTIONS

200

WELD WFS

HI = 200 LO = 180

WELD MODE
ARC CONTROL

START OPTIONS
END OPTIONS

200

Memory Value

Parameter Name

Low Limit

High Limit

The memory value must always be less than or equal

to the high limit, and greater than or equal to the low

limit.

After setting limits, press the memory button with the

flashing LED. The MSP4 will ask to save or discard

the limit changes just made. Press the left MSP4 for

button (YES) to save and enable the limits and exit.

Press the right MSP4 button (NO) to exit and leave

limits unchanged.

Enabling/Disabling Limits

Limits for each memory may be enabled or disabled

by pressing and hold the appropriate memory button

for 10 seconds. Release the memory button when the

MSP4 display shows the following:

If the passcode does not equal zero, enter the passcode

now. If the passcode is zero (0000), SETUP will light

and the MSP4 displays the following:

Press the left MSP4 button (YES) to enable limits or

the right MSP4 button (NO) to disable limits. Disabling

limits does not change any limits values that may

have been previously set.

A GUN B

1

5

2

6

3

7

4

8

Enable/Disable

Limits: Press

10 seconds

Rotate to

Change

Value.

Press to

select item

to change.

MEMORY 2 LIMITS

ENABLE/DISABLE

WELD MODE
ARC CONTROL

START OPTIONS
END OPTIONS

ENABLE LIMITS?

WELD MODE
ARC CONTROL

START OPTIONS
END OPTIONS

Yes No

Advertising