Operation, Setup menu features parameter, Definition – Lincoln Electric POWER FEED IM892-C User Manual

Page 41

Advertising
background image

B-25

OPERATION

B-25

POWER FEED™ 25M

SET-UP FEATURES MENU

(See Figure B.17b and B.17c for specific Codes)

1. To access the set-up menu, press the Right and

Left buttons of the MSP4 panel simultaneously.

Note that the set-up menu cannot be accessed if

the system is welding, or if there is a fault (The sta-

tus LED is not solid green).

Change the value of the blinking parameter by rotat-

ing the SET knob.

2. After changing a parameter it is necessary to press

the Right hand button to save the new setting.

Pressing the Left button will cancel the change.

3. To exit the set-up menu at any time, press the

Right and Left buttons of the MSP4 panel simulta-

neously. Alternately, 1 minute of inactivity will also

exit the set-up menu.

The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters

that generally only need to be set at installation. The parameters are grouped as shown in the following table.

SETUP MENU FEATURES

PARAMETER

P.1 through P.99

P.101 through P.199

P.501 through P.599

DEFINITION

Unsecured Parameters (always adjustable)

Diagnostic Parameters (always read only)

Secured Parameters (only accessible through a p.c. or palm application)

LED

Indicator

Mode Select

Panel (MSP4)

Right

button

SET Knob

Left

buttom

LED

Indicator

Mode Select

Panel (MSP4)

Right

button

SET Knob

Left

buttom

FIGURE B.17b - SETUP MENU

(Only parameters below can be accessed in Code 11313)

P.0

P.7

P.100 thru P.107

P.1

P.8

P.2

P.11

P.3

P.12

P.4

P.13

P.5

P.80

P.6

P.99

FIGURE B.17c - SETUP MENU

(All parameters can be accessed in Code 11456 and higher)