Operation – Lincoln Electric POWER FEED IM892-C User Manual

Page 21

Advertising
background image

B-5

OPERATION

B-5

POWER FEED™ 25M

FIGURE B.1a

CASE FRONT CONTROLS

(CODE 11456 and

higher) (See Figure B.1a)

1. Left DISPLAY window

Shows WIRE FEED SPEED or AMPERAGE.

2. Left KNOB

Adjusts values in left display.

3. Status LED

Illuminates a steady green when communicating to

the power source properly.

4. MSP4 display window

Shows detailed welding and diagnostic information.

5. Left Button

Changes the MSP4 display to show the Weld Mode

or Arc Control.

6. Procedure Button

Selects A or B procedure, or gun control.

7. 2-Step/4-Step Button

Toggles between 2-step and 4-step trigger opera-

tion.

8. 5-pin connector

Trigger connector for a push-only gun.

9. ON/OFF switch

Controls power to the POWER FEED™ 25M.

10. 6-pin connector

Connector for a remote control.

11. Cover

Covers location for optional water cooling line.

12. 7- pin connector

Connector for a push-pull gun.

13. Right Display window

Shows VOLTAGE or TRIM.

14. Right Knob

Adjusts values in the right display.

15. Thermal

Lights when the drive overheats.

16. Set-Up

Lights when feeder is set-up

17. IR port

Used to transfer information to palm computers,

etc.

18. Right Button

Changes the MSP4 display to show Start Options

or End Options.

19. Set Knob

Changes the value on the MSP4 display.

20. Memory Buttons

(For selection of common procedures.)

1

13

2

3

14

4

17

18

19

20

10

11

12

16

5

7

8

9

6

15

Advertising