background image

B-8

B-8

POWER FEED™ 25M

START OPTIONS
END OPTIONS

SET

SETUP

IR PORT

CC Stick Soft

WAVEFORM CONTROL TECHNOLOGY

Stick

WELD MODE

ARC CONTROL

I

I

ARC FORCE

(Soft)-10.0 to

(Crisp)+10.0

DESCRIPTION

START TIME:

0 to 10 seconds

FUNCTION

If no remote control is installed,

this control sets the time for

the weld output to ramp up or

down from a preset Start cur-

rent to the preset Weld current.

Use the WFS/AMP knob to

adjust Start current while the

Start Options LED is displayed.

No arc ending options are active for

SMAW (Stick) welding modes.

PROCESS

Stick Soft(7018)

Stick Crisp(6010)

MODE

1

2

CC STICK MODES

START OPTIONS

END OPTIONS

ARC CONTROL

Lower values will provide less short

circuit current and a softer arc.

Higher settings will provide a higher

short circuit current, a more forceful

arc and possibly more spatter.

194

0

WFS AMPS

VOLTS TRIM

LESS

AMPS

MORE

AMPS

OUTPUT

OFF

OUTPUT

ON

n

FIGURE B.3

MSP4 OPERATION

SMAW (Stick) Welding Display