PROCEDURE

1. Remove input power to the POWER WAVE

355M/405M.

2. Using a 5/16” nut driver remove the case wrap-

around cover.

3. Perform the Input Filter Capacitor Discharge

Procedure detailed earlier in this section.

4. Locate the snubber board.. See Figure F.23.

5. Remove small lead #B1 from the board. See

Figure F.24.

6. Remove the four bolts using a 7/16” socket. Two

of these bolts have leads #30 and #10 connected
to them. Note the position of all leads and associ-
ated washers upon removal.

7. Carefully remove the snubber board.

8. Replace the snubber board.

9. Replace the bolts, leads, and washers previously

removed. Torque bolt to 30-40 Inch Lbs.

10. Reconnect small lead B1 previously removed.

11. Replace the case wraparound cover.

LEFT SIDE

Snubber

Board

FIGURE F.23 – SNUBBER BOARD LOCATION

Lead B1

Lead 30

Lead 10

FIGURE F.24 – SNUBBER BOARD LEADS (CLOSE UP)