Symptoms, The machine is dead—no output—no led’s, The main input fuses (or breaker) repeatedly fail – Lincoln Electric POWER WAVE 355M User Manual

Page 50: Troubleshooting and repair, Caution

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

TROUBLESHOOTING AND REPAIR

F-4

F-4

POWER WAVE 355M/405M

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Section

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Retur

n

to

Master

T

OC

Major physical or electrical damage
is evident when the sheet metal
cover is removed.

1. Contact your local authorized

Lincoln Electric Field Service
Facility for technical assistance.

1. Contact the Lincoln Electric

Service Department,
1-888-935-3877.

The machine is dead—no output—
no LED’s.

1. Make sure the input line switch is

in the ON position.

2. Check the main input line fuses.

If open , replace.

3. Check the 15 amp circuit break-

er (CB1). Reset if tripped. Also
check CB3.

4. Make sure the reconnect switch

and jumper lead is configured
correctly for the applied input
voltage.

5. If the machine is being operated

with single phase input voltage
make sure the correct lead is not
connected. See the Installation
Section
.

1. Perform the Auxiliary Trans -

former Test.

2. Perform the DC Bus Board Test.

2. Perform the Power Board Test.

3. The Bus Board rectifier and or

associated filter capacitor (C5)
may be faulty. Check and
replace as necessary.

4. The Control Board may be faulty.

The main input fuses (or breaker)
repeatedly fail.

1. Make certain the fuses or break-

ers are sized properly.

2. Make sure the reconnect switch

and jumper lead is configured
correctly for the applied input
voltage.

3. The welding procedure may be

drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and /or reduce the duty
cycle.

1. Check the reconnect switches

and associated wiring. See the
Wiring Diagram.

2. Perform the Input Rectifier

Test.

3. Perform the Main Switch Board

Test.

4. Perform the Output Diode

Module Test.

5. The Input Filter Capacitors may

be faulty. Check, and if any are
faulty replace all four.

Advertising