AUXILIARY TRANSFORMER TEST (continued)
TEST PROCEDURE
1. Remove input power to the POWER WAVE
355M/405M.
2. Using a 5/16” nut driver, remove the case
wraparound cover.
3. Perform the Input Capacitor Discharge
Procedure detailed earlier in this section.
4.
Locate the auxiliary transformer. See Figure
F.10.
5.
Locate the secondary leads and plug P52.
See Figure F.10 and F.11.
FIGURE F.10 Auxiliary Transformer
FIGURE F.11 Plug Lead Connections Viewed From Transformer Lead Side of Plug