Troubleshooting and repair, Warning – Lincoln Electric POWER WAVE 355M User Manual

Page 70

Advertising
background image

TEST PROCEDURE

1. Remove input power to the Power Wave

355M/405M.

2. Using the 3/8” nut driver, remove the case

top.

3. Perform

the

Capacitor

Discharge

Procedure.

4. Locate the Power Board and plugs J42 and

J43. Do not remove plugs or leads from
the Power Board
. Refer to Figure F.8.

5. Carefully apply input power to the Power

Wave 355M/405M.

ELECTRIC SHOCK can kill.

High voltage is present when

input power is applied to the

machine.

6. Turn on the Power Wave 355M/405M.

Carefully test for the correct voltages at the

Power Board according to Table F.4.

7. If either of the 40 VDC voltages is low or not

present at plug J41, perform the DC Bus PC
Board Test
.
See the Wiring Diagram. Also
perform the T1 Auxiliary Transformer
Test.

8. If any of the DC voltages are low or not pre-

sent at plugs J42 and/or 43, the Power

Board may be faulty.

9. Install the case top using the 3/8” nut driver.

TROUBLESHOOTING AND REPAIR

F-24

F-24

POWER WAVE 355M/405M