SYSTEM SET-UP

Basic Rules
• Each group is required to have one user interface. No

group may have more than one user interface.

• Each group can have up to seven Feed Heads.

Exception: Group 3 is limited to a maximum of six
Feed Heads.

• Each system has only one power source. For network

purposes, the PS belongs to Group 3, which is why

group 3 is only allowed 6 feed heads in addition to it’s

user interface.

• No two feed heads can have identical Group and

Feed Head numbers.

• Group and Feed Head ID numbers must be set on the

appropriate dip switches at each node. Consult the

PF-10/11 Instruction Manual for specific details

regarding dip switch settings.

• Feed head “0” not allowed. Exception: Simple sys-

tem ignores all ID numbers, therefore “FH0” will func-

tion.

• Each node must be connected to the Linc-Net com-

munication network. The order of connection is not

important, as each node is identified by it’s unique

Group and Feed Head ID number as defined on it’s

dip switches. See Figures A.2 thru A.5.

FIGURE A.2

Simple System

Group

and

Feed

Head ID numbers are

ignored in a simple

system.