B-19

“TX-TBIC outage error(s) detected IER1=0x%x, IER2=0x%x,”

LOG_FILE:

/var/log/gr.console

SOURCE_FILE:

tx/tbsi_svc.c

SCOPE:

CARD

CONTEXT:

RUNNING

SEVERITY:

FATAL

DESCRIPTION: This message is logged when a TBIC outage error occurs. The TBICs
are reset and the state machine goes back to CONFIGURED state. The SP Switch Router
Adapter card treats TBIC outage errors as permanent errors.

“TX-TBIC permanent error(s) detected IER1=0x%x, IER2=0x%x,”

LOG_FILE:

/var/log/gr.console

SOURCE_FILE:

tx/tbsi_svc.c

SCOPE:

CARD

CONTEXT:

RUNNING

SEVERITY:

FATAL

DESCRIPTION: This message is logged when a TBIC permanent error occurs. The
TBICs are reset and the state machine goes back to CONFIGURED state.

“TX-TBIC transient error(s) detected IER1=0x%x, IER2=0x%x,”

LOG_FILE:

/var/log/gr.console

SOURCE_FILE:

tx/tbsi_svc.c

SCOPE:

CARD

CONTEXT:

RUNNING

SEVERITY:

INFO

DESCRIPTION: This message is logged when a TBIC transient error occurs.

“Un-expected descriptor from RC, desc_type=%d.”

LOG_FILE:

/var/log/gr.console

SOURCE_FILE:

rx/tbsi_svc.c

SCOPE:

CARD

CONTEXT:

RUNNING

SEVERITY:

WARNING

DESCRIPTION: This message is logged when the RX-CPU receives a descriptor that is
expected by the CPU in its current state. Reset/reload the card if the card could not be
brought on-line.

“Un-expected descriptor from TC, desc_type=%d.”

LOG_FILE:

/var/log/gr.console

SOURCE_FILE:

tx/tbsi_svc.c

SCOPE:

CARD

CONTEXT:

RUNNING

SEVERITY:

WARNING

DESCRIPTION: This message is logged when the TX-CPU receives a descriptor that is
expected by the CPU in its current state. Reset/reload the card if the card could not be
brought on-line.