Polaris TBM 200 LH User Manual

Page 39

Advertising
background image

3

by pounding as this will damage the seal. When

removing impeller warm slightly with a torch

and pry impeller off evenly with either small

pry bars or a wheel puller.

When the submersible pump motor leaves the

factory it is ready for installation. No adjustment,

venting or oil filling is required. For THREE

PHASE motors the only connection to the motor

lead cable is the power supply. For SINGLE

PHASE motors the motor lead cable and power

supply must be properly connected at the

Control Box. Motor will operate successfully with

frequency not more than 5% and voltage not

more than 10% above or below nameplate data.

Performance within this range will not necessarily

be the same as the established performance at

exact rated voltage and frequency.

All submersible pump motors will operate in

either direction of rotation. To reverse direction

of a THREE PHASE motor, interchange any

two motor leads at the starter. To reverse

direction of rotation of a SINGLE PHASE motor

the proper connections must be made in the

motor connection chamber; refer to the W/D's

supplied in the motor connection chamber and

Control Box.

Lifting eyes are supplied for purpose of

installation and servicing. (Do not usemotor

lead cables for lifting means.) Normal care

should be exercised to prevent mechaniĆ

cal damage to the seal, the frame and the

insulated cable.

LIFT MOTOR ONLY USING BOTH ATTACHMENT POINTS.

EYENUTS & EYEBOLTS MUST BE SEATED & IN LINE AS

SHOWN BELOW.
PREFERRED METHOD - USE SPREADER BAR.

WARNING

4

45°

MAX.

692.FF

STARTING

CAUTION: Surface temperature of motor

enclosure may reach temperatures which can

cause discomfort or injury to personnel acciĆ

dentally coming into contact with hot surĆ

faces. (When installing, protection should be

provided by user to protect against accidental

contact with hot surface) .

On initial start up the motor and pump should

be checked for proper rotation prior to final

application.
The unit is designed to protect all power connecĆ

tions against moisture. All Reliance Submersible

Pump Motors have a lead connection chamber.

- THREE PHASE dual voltage motors have 9

motor leads and SINGLE PHASE dual voltage

motors have 8 motor leads in this chamber. All

Submersible Pump Motors have 2 thermal proĆ

tector leads and 2 moisture sensing probe leads

in this chamber.
Leads are tagged for easy identification. A conĆ

nection diagram is provided in the lead chamber.

Motors can be connected for either high or low

voltages. (Some motor ratings are built as single

voltage units and as such are not reconnectable).
The motor lead cable assembly for all

Submersible Pump Motors has 3 marked power

leads plus two ground leads, two thermal leads

and two moisture sensing probe leads in

standard cable lengths of 25 feet.
Leads are brought through an epoxy sealed conĆ

nector providing a mechanically strong water tight

seal. The cap and cable assembly are available

from Reliance Electric as a replacement part asĆ

sembly. When replacing the lead wire cap, care

should be taken not to nick or damage the O" ring

seal. Replace any damaged or nicked O" rings.

WHEN REPLACEMENT CABLE ASSEMBLY IS

REQUIRED, ORDER FROM RELIANCE ELECĆ

TRIC CO. USING MOTOR IDENTIFICATION

NUMBER.