139 combination connection – Pioneer Plasma Display Monitor 502MX User Manual
Page 139
Advertising
139
Combination Connection
If the following connection conditions are observed, extension of operations to as many as 16 units is guaranteed.
Conditions:
1 Length of RS-232C cable connecting PC to PDP-502MX: 5 m
2 Combination cable length: 5 m for each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)
For 1 strand, suitable for AWG28:
Cross-section area = 0.08 mm
2
≠
7 strands
×
π
r
2
= 7
Ч
3.14
Ч
0.06
2
= 0.079 mm
2
≠ 0.08 mm
2
(NOTE) Refer to section 2.3, “Controls and Connectors” regarding the number of units that can be connected when
series connection is made while using a video output terminal (INPUT 1 or 4).
PC
RS-232C
Combination cable 5m
PDP-502MX
1
2
3
#
OUT
IN
OUT
IN
OUT
IN
5m
Advertising