139

Combination Connection

If the following connection conditions are observed, extension of operations to as many as 16 units is guaranteed.

Conditions:

1 Length of RS-232C cable connecting PC to PDP-502MX: 5 m
2 Combination cable length: 5 m for each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)

For 1 strand, suitable for AWG28:

Cross-section area = 0.08 mm

2

7 strands

×

π

r

2

= 7

Ч

3.14

Ч

0.06

2

= 0.079 mm

2

≠ 0.08 mm

2

(NOTE) Refer to section 2.3, “Controls and Connectors” regarding the number of units that can be connected when

series connection is made while using a video output terminal (INPUT 1 or 4).

PC

RS-232C

Combination cable 5m

PDP-502MX

1

2

3

#

OUT

IN

OUT

IN

OUT

IN

5m