Self-test results, Refer to table 4-2, Self-test results messages – Paradyne Hotwire 7975 User Manual

Page 48

Advertising
background image

Monitoring the Unit

4-4

7975-A2-GB20-40

December 1998

Table 4-1.

Health and Status Messages

Message

What To Do

What Message Indicates

Net Com Link
Down

The Network communication
link is down. Communications
between the management
system and the LTU/NTU is
not possible.

1. Verify that the network cable is

securely attached at both ends.

Mismatch Rate,
Pt 1

The LTU, in fixed rate, is
attempting to communicate at
a faster rate than the NTU
can handle.

If the LTU is a 2 Mbps product:

1. Verify endpoint is not a 1 Mbps

product

2. Upgrade remote unit to a 2 Mbps

Self-Test Results

The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.

Table 4-2.

Self-Test Results Messages

Message

What Message Indicates

What To Do

CPU Failed

The CPU failed internal testing.

1. Reset the unit and try again.

DeviceFailed

One or more of the 7975 Standalone
Termination Unit’s integrated circuit
chips has failed device-level testing.

2. Call your service

representative for assistance.

Net DSL
Failed, Pt 1

The 7975 Standalone Termination
Unit failed to loop data on the
network DSL circuit of Port 1.

1. Reset the unit and try again.

2. Call your service

representative for assistance.

SYNC Pt
Failed, Pt 1

The 7975 Standalone Termination
Unit failed to internally loop data on
the synchronous Port 1.

re resentative for assistance.

Memory
Failed

The 7975 Standalone Termination
Unit failed memory verification.

Failure
xxxxxxxx

An internal failure occurred.
(xxxxxxxx represents an 8-digit
hexadecimal failure code for use by
service personnel.)

Record the failure code and
contact your service
representative.

Passed

No errors were detected.