Paradyne Hotwire 7975 User Manual

Page 77

Advertising
background image

Security

7-5

7975-A2-GB20-40

December 1998

Limiting SNMP Access through the IP Addresses of the Managers

The unit provides an additional level of security through validation of the IP
addresses.

The SNMP Management option must be enabled. To control SNMP access with
IP addresses, follow this menu selection sequence:

Main Menu

Configuration

Management

Security Menu

Refer to Table A-9,

SNMP NMS Security Options

. The SNMP access can be

limited by:

H

Enabling NMS IP address checking.

H

Add each IP address and access level.

NOTE:

Do not change or delete the IP address or access level of the NMS
performing the sets or enable IP address checking prior to adding the NMS to
the table.

Resetting the Termination Unit’s COM Port or
Factory Defaults

Misconfiguring the termination unit could render the user interface inaccessible,
leaving it in a state where a session cannot be started via the COM port or a
Telnet session. If this occurs, the termination unit connectivity can be restored via
a terminal directly connected to the COM port.

Two methods can be used to restore access to the user interface:

H

Reset COM Port – Allows you to reset the configuration options related to
COM port usage. This also causes a device reset, where the termination unit
performs a Device Self-Test. No security-related configuration options are
changed.

H

Reload Factory Defaults – Allows you to reload the Default Factory
Configuration, resetting all of the configuration and control settings which
causes the current configuration to be destroyed and a device reset. This
method is also useful when the user’s password(s) have been forgotten.

"

Procedure

To reset COM port settings:

1. At the terminal that is directly connected to the unit’s COM port, configure the

terminal to operate at 9.6 kbps, using character length of 8 bits, with one
stop-bit, and no parity.

2. Reset the unit, then immediately and repeatedly press Enter at a rate of

about 1 press per second until the System Paused screen appears.

3. Tab to the desired method, and enter yes (or y) for the selected prompt.

Advertising