Messages and Troubleshooting

6-4

7975-A2-GB20-40

December 1998

Table 6-1.

Device Messages (2 of 2)

Device Message

What To Do

What Message Indicates

Invalid entry at cursor
(1...223, excluding
127)

Invalid range.

Enter a value within the IP
address range.

Limit of six Login IDs
reached

An attempt to enter a new
login ID was made, and the
limit of six login/password
combinations has been
reached.

1. Delete another login/password

combination.

2. Reenter the new login ID.

No Security Records
to Delete

Delete was selected from
the Administer Login
screen, and no security
records had been defined.

H

No action needed.

H

Enter a security record.

Password Matching
Error – Re-enter
Password

Password entered in the
Reenter Password field of
the Administer Logins
screen does not match
what was entered in the
Password field.

H

Try again.

H

Contact your system
administrator to verify your
password.

Please Wait

Command takes longer
than 5 seconds.

Wait until message clears.

Test Active

A test is running and no
higher priority health and
status messages exist.

H

Contact service provider if test
initiated by the network.

H

Wait until the other test ends
and message clears.

H

Cancel all tests from the Test
screen.

H

Stop the test from the same
screen the test was started
from.

0.0.0.0 is an invalid
IP address

An IP address of all zeroes
was entered.

Enter a valid, non-zero IP
address.