System options menu, System options, Table a-3 – Paradyne Hotwire 7975 User Manual

Page 87: Able a-3, And t, General system options of

Advertising
background image

Configuration Option Tables

A-7

7975-A2-GB20-40

December 1998

System Options Menu

For System Options, refer to Table A-3. To access the System Options screen,
follow this menu selection sequence:

Main Menu

Configuration

Load Configuration From

System

Table A-3.

System Options

DSL Mode

Possible Settings: LTU, NTU
Default Setting: NTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.

NOTE:

Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows user-initiated tests to end automatically. The feature should be enabled when the
unit is remotely managed, so that control can be regained after a test is accidentally
executed.

Enable – User-initiated loopback and pattern tests end when test duration is reached.

Disable – Tests can be terminated manually from the Network Tests screen. Refer to

Running Network Tests

in Chapter 5,

Testing.

NOTE:

Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.

Test Duration (min)

Possible Settings: 1–120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

H

The Test Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.