Configuration Option Tables

A-8

7975-A2-GB20-40

December 1998

Communication Port

For Communication Port Options, refer to Table A-4. To access the
Communication Port screen, follow this menu selection sequence:

Main Menu

Configuration

Load Configuration From

Communication

Port

Table A-4.

Communication Port (1 of 3)

Port Use

Possible Settings: Terminal, Net Link
Default Setting: Terminal

Specifies how the communications port is to be used.

Terminal – The communication port will be used for an Asynchronous terminal
interface.

Net Link – The communication port will be used as the network communication link to
an IP network or device.

Port Type

Possible Settings: Asynchronous, Synchronous
Default Setting: Asynchronous

When Port Use is set to Net Link, Port Type controls whether the communication port
will be asynchronous or synchronous.

Asynchronous – Configures the communication port for asynchronous communication.

Synchronous – Configures the communication port for synchronous communication.

NOTE:

Peer IP Address and Circuit Identifier are

not copied.

Data Rate

Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4
Default Setting: 9.6

Specifies the communication port baud rate.

9.6 – Communication port rate is 9600 bps.

14.4 – Communication port rate is 14400 bps.

19.2 – Communication port rate is 19200 bps.

28.8 – Communication port rate is 28800 bps.

38.4 – Communication port rate is 38400 bps.

Parity

Possible Settings: None, Odd, Even
Default Setting: None

Specifies the parity of the communication port.

None – No parity used.

Odd – Odd parity used.

Even – Even parity used.