Ending an active test – Paradyne Hotwire 7975 User Manual

Page 66

Advertising
background image

Testing

5-12

7975-A2-GB20-40

December 1998

Ending an Active Test

Except for the Remote Send Line Loopback and Remote DCLB, a test initiated by
the user can be ended by the user. Tests can also be terminated automatically by
enabling the Test Timeout option from the System Options Menu.

H

A Test Timeout option is available to automatically terminate a user-initiated
Loopback or Pattern test (as opposed to manually terminating a test) after it
has been running a specified period of time. The default is 10 minutes.
Refer to Table A-3,

System Options

.

Test Timeout does not pertain to tests initiated by the network.

H

On each test screen is a Command column. To stop the test, Press Enter
when the cursor is on the Stop command.

H

Use the Abort All Tests selection from the Test menu to stop all tests running
on all interfaces, with the exception of network-initiated loopbacks.

Command

Complete

appears when all tests on all interfaces have been terminated.

An aborted test may continue to run for a few seconds as the abort command
is sent to the remote end and processed.