8310 MVL and 8510 DSL Card Configuration

5-8

8000-A2-GB26-00

May 1998

"

Procedure

To view DSL card information and configure Maximum Transmission Unit (MTU)
settings or restart, stop, or monitor an interface:

1. Follow this menu sequence:

Configuration

Interfaces (A-C)

2. The Interfaces menu appears. Enter the desired value on each selected

screen and field as shown in Table 5-3 and press Return.

Table 5-3.

Interfaces Options

General (General Interfaces)

A-C-A

Gives the user the ability to view basic card interface information about a given
interface.

Interface Name – 3 characters. e1a = Ethernet port; s1c, s1d, s1e and s1f = DSL or
MVL interface.

Type – Static/Dynamic. Interface type.

Protocol – HDLC or Ethernet. Interface protocol.

Port List – Ports available on the card.

MTU (max) – 64–1600 bytes (Default = 1536).

NOTE:

The above MTU values are the only values you may enter. Make certain
that if you change from the default value, the new numbers are appropriate
to your network. Do a card reset or reset the Ethernet interface.

Control (Control Interfaces)

A-C-B

Gives the user the ability to start, stop, and monitor (up, down, or testing) the current
state of an interface.

NOTE:

Stopping the interface disables all of the traffic on that port, including
diagnostics. If you want to only disable customer traffic, instead disable all
VLANs on that port.

There are no user-configurable elements on this screen except for the ability to start
and stop the interface. Valid choices for the DSL card are e1a, s1c, s1d, s1e, and s1f.

DSL Configuration Users Screens

Use the system information submenu of the Users screens to configure login
accounts for Telnet sessions directly to the DSL cards.

This menu item is not currently supported on this card.