Paradyne HOTWIRE 8310 MVL User Manual

Page 79

Advertising
background image

Diagnostics and Troubleshooting

7-5

8000-A2-GB26-00

May 1998

Table 7-2.

Major Alarms (2 of 2)

Failure Type

Action

Ethernet port
failure

1. Check cable connections to the DSLAM.

– If cables are terminated properly, go to Step 2.

– If cables are not terminated properly, terminate them correctly.

2. Check cable connections to the Hub or Ethernet switch.

– If cables are terminated properly, go to Step 3.

– If cables are not terminated properly, terminate them correctly.

3. Check the Activity/Status LED at the Ethernet Hub or Switch

.

– If Activity/Status LED does not indicate a problem, go to Step 4.

– If Activity/Status LED indicates a problem, take appropriate

action.

4. Disconnect the Ethernet cable and replace it with a working cable

from a spare port on the Hub.

– If the replacement cable works, the original is bad and should be

permanently replaced.

– If the replacement cable does not work, reconnect the original

cable and go to Step 5.

5. Move the DSL card and cable to another (spare) slot.

– If this solves the problem, the connector or interface panel

connections for the original slot are bad. Schedule maintenance
for the chassis and try to use the spare slot temporarily.

– If this does not solve the problem, the DSL card is probably bad

and should be replaced.

DSL port
failure

1. Check the Selftest Results display by following the menu sequence:

Diagnostics

Selftest.

2. Do another Selftest (Reset) and check results.

– If the results are normal, the problem was transient. Log the

results.

– If the results are the same as the first selftest, the card should be

replaced. If only one port on a DSL card is bad, that port can be
disabled. You may continue to use the card until it is convenient
to replace it.

DSL card not
responding

(LEDs on card
are out or MCC
is showing an
alarm.)

1. Check to see if the lights are out on the card.

– Plug the card into an empty slot to see if it responds. If not, the

card is bad and needs to be replaced.

– If the card responds in a different slot, the slot connector may be

bad. Call your service representative.

2. Check to see if the lights are on, but not responding.

– Pull the card out and plug it in again.

– Reset the card from the MCC or DSL Main Menu.

– Go to the MCC Main Menu and clear NVRAM.

– Replace the card.

Advertising
This manual is related to the following products: