Paradyne HOTWIRE 8310 MVL User Manual

Page 91

Advertising
background image

Traps

B-3

8000-A2-GB26-00

May 1998

Event

Trap # – MIB *

Comment

Trap Class

xDSL test start

normal

Test started by any
means.

6–dsl

xDSL test clear

normal

Test over.

106–dsl

DHCP filter security failure

minor

Can not add new
route to route table
because maximum
number of stored
rules reached.

11–dhcp

SN device mismatch

minor

SN identified on port
N does not match
device described in
port configuration
role.

07–dsl

SN device mismatch clear

minor

SN identified on port
N now matches
device described in
port configuration
table.

107–dsl

SN loss of power

minor

Card received “last
gasp” message from
SN, followed by a
link down condition
one minute later.

17–dsl

SN device failure

major

Operating software
has detected an
internal device
failure. The SN is still
operating.

18–dsl

SN selftest failure

minor

Failure of the SN’s
hardware
components. This
trap is only sent if
the hardware failure
still allows sending
traps.

19–dsl

SN fatal reset

—-

Variable binding field
contains device
failure code.

20–dsl

Dynamic filter injection
failure

warning

Cannot inject or
delete dynamic filters
to SN on port N.

10–dhcp

* MII = MIB ll, ent = Entity MIB, dsl = hotDSL Enterprise MIB, sys = hotSys Enterprise

MIB, dhcp = DHCP Enterprise MIB, diag = hot_diag.mib

Advertising