Rs-232c, Query control commands – Panasonic DVCPRO AJ-D250P User Manual

Page 58

Advertising
background image

[STX] QLH:m [ETX]

Parameters
m = D: Cumulative drum rotation

time

T: Cumulative capstan rotation

time

No parameter:

Cumulative drum rotation
time (4 digits)

[STX] LHRdata [ETX]

data = mhhhhh
m = D: Drum

T: Capstan

hhhhh = 00000

99999:

Cumulative rotation time

O

With no parameter

The drum’s cumulative rotation time
is returned as a 4-digit value.
data = hhhh
hhhh = 0000

9999:

Cumulative rotation time

Queries the current value of the hours meter.

[STX] QOT [ETX]

[STX] OTEm [ETX]

m = E:

E-E (Electric modulation to Electric
play back)

m = T:

V-V (VTR to VTR recording)

Queries whether to set to the E-E output or V-V output
when the VTR is in the STOP mode, FF mode or REW
mode.

58

RS-232C

$

Query control commands

Sends data of computer

Return data from VTR

Description of command

[STX] QIE [ETX]

[STX] IEVdata [ETX]

data = m1m2
m1 = 0

F: Designates the data of bit 7

to bit 4.

m2 = 0

F: Designates the data of bit 3

to bit 0.

Queries the forced E-E output setting.

Parameter

m1 (HEX display)

m2 (HEX display)

Bits supported

BIT7

BIT6

BIT5

BIT4

BIT3

Switching data

0

0

0

0

AUDIO CH1

BIT2

AUDIO CH2

BIT1

VIDEO

BIT0

TC

Advertising