Error Messages

When a problem has occurred in the unit, one of the following error messages will appear on the tape
counter.

Error No.

Description

— d —

Condensation (dew) has formed.

E — 00

E — 01

E — 11

E — 21

Four or more 4 seconds have elapsed after the
cassette was inserted but the cassette is not
lowered down inside the unit.
Alternatively, 4 or more seconds have elapsed after
the eject operation was initiated but the cassette is
not ejected.

E — 31

The loading operation is not completed within 4
seconds.

E — 32

The unloading operation is not completed within 4
seconds.

E — 41

The FG signal (rotational speed signal) is not output
from the cylinder motor.

E — 42

The PG signal (phase signal) is not output from the
cylinder motor.

E — 43

The cylinder motor speed is abnormally high.

E — 44

The cylinder motor speed is abnormally low.

E — 51

The FG signal (rotational speed signal) is not output
from the capstan motor.

E — 52

The capstan motor speed is abnormally high.

Error No.

Description

E — 66

The start or end processing operation fails to be
completed even after 7 or more seconds have
elapsed.

E — 67

A communication error between SERVO and
AVSYS. Errors in the data.

E — 68

A communication error between SERVO and
AVSYS. The data is fixed at high or low.

E — 69

A problem in communication between SERVO and
AVSYS when the power was switched on.

E — 70

The reel base which operates in line with the size of
the tape has been locked for 2.5 or more seconds.

E — 53

The capstan motor speed is abnormally low.

E — 61

The supply (S) reel motor is locked.

E — 62

The take-up (T) reel motor is locked.

E — 63

The supply reel motor speed is abnormally high.

E — 64

The take-up reel motor speed is abnormally low.

E — 65

Abnormal tension has been detected.

E — 09

Appears when the servo fails to lock for 3 or more
seconds.
When T&S&R is selected as the setup menu item
No.001 setting, “SERVO NOT LOCKED” is
displayed on the third line (line where the remaining
tape amount is indicated) of the monitor screen.

Appears when there is no head output for one or
more seconds (due to clogging, etc.).
“L” is displayed on the first line (counter line) of the
monitor screen.
When T&S&R is selected as the setup menu item
No.001 setting, “LOW RF” is displayed on the third
line (line where the remaining tape amount is
indicated) of the monitor screen.

Appears when a blank area on the tape has been
detected.
“N” is displayed on the first line (counter line) of the
monitor screen.
When T&S&R is selected as the setup menu item
No.001 setting, “NO RF” is displayed on the third
line (line where the remaining tape amount is
indicated) of the monitor screen.
When all the following conditions are met, the part of
the tape is recognized as a blank.

O

No output from any of the heads

O

Playback data cannot be read

O

No CTL signal

The fan motor has stopped.
“S” is displayed on the first line (counter line) of the
monitor screen.
When T&S&R is selected as the setup menu item
No.001 setting, “FAN STOP” is displayed on the
third line (line where the remaining tape amount is
indicated) of the monitor screen.
When about an hour elapses, the unit is shut down
automatically.

E — 6B

This appears when there is a communication error
between IF and AVSYS. There is a problem with the
internal reference or external reference.

E — 72

There is a problem in the solenoid drive circuit.

E — 73

There is a problem in the cleaning solenoid drive
circuit.