5 radio tab, Idle poll limit, Power off time – Psion Teklogix Vehicle-Mount Computer 8525 G2 User Manual

Page 140: Modulation/baud rate

Advertising
background image

Chapter 5: Configuration
Narrow Band Radio Setup

116

Psion Teklogix 8525 G2/8530 G2 Vehicle-Mount Computer User Manual

Idle Poll Limit

Note: The “Idle Poll Limit” parameter is only used when “Enable Power

Saving” is enabled.

This parameter determines how many transmit opportunities – base station polls
with available response windows – must be consecutively skipped before the 8525
G2/8530 G2 places the radio into power-down mode for power saving. The
allowable range for this parameter is from 1 to 200. The default value is 10.
Lower values cause the vehicle-mount to enter power saving mode quickly,
extending battery life but reducing 8525 G2/8530 G2 responsiveness. Higher values
increase responsiveness but decrease battery life.

Power Off Time

This parameter determines the amount of time (in seconds) the 8525 G2/8530 G2
radio stays in power-down mode when a power down period has been initiated.
“Power Off Time” is only used when the “Enable Power Saving” parameter is
enabled.
The allowable range for this parameter is 1 to 60.

5.5.8.5

Radio Tab

Modulation/Baud Rate

The options in the Modulation / Baud Rate dropdown menu are: 2 Level/4800,
2 Level/9600, 4 Level/9600 and 4 Level/19200. The value assigned to this
parameter must be identical to the corresponding parameter in the Psion Teklogix
Base Station. This parameter is stored in the radio’s non-volatile memory. The
default value for Modulation/Baud Rate is 2 Level/9600

Advertising