• Now the built-in time code generator is locked to the

reference time code.

• When locked to an external time code generator, the

time code is at all times locked to the external time code,
which is displayed as a highlighted value on the counter
indicator. Do not engage the recording mode during the
few seconds it takes for the sync generator to stabilize.

• Once a slave relationship is established, the TC IN and

GENLOCK IN connectors stay in slave status.*
Note that the following events release slave status.

• When TC PRESET is performed
• When the REC SIGNAL option in the SYSTEM SETUP

screen is set to 1394.

• The power is turned off
• The time code mode is switched
• The TCG switch is set to R-RUN
• When REC FORMAT and CAMERA MODE have been

switched

* The slave function locks the time code to the TC IN

input and the device will use this time code even if time
code input should subsequently cease.

Setting the user bits when the time code
is externally locked

To externally lock user bits, set the setting menu UB MODE
(RECORDING SETUP screen) to EXT.
Regardless of an F-RUN or R-RUN setting of the TCG
switch, the time code is slaved to user bit values input to
the TC IN connector.
For details, refer to [Setting Time Data] (page 56) and
[Setting user bits] (page 58).

To unlock the externally locked time code

Discontinue external time code supply, then position the
TCG switch at [R-RUN].

Cautions in switching the power source
from battery to external power supply

Connect the DC IN socket with the external power supply
before removing the battery, in order to keep the time code
generator energized. If the battery is removed first, there is
no guarantee that the time code will stay externally locked.

External synchronisation of the camera
when the time code is externally locked

When the time code is externally locked, the reference
video signals input through the GENLOCK IN connector
gen-lock the camera.

NOTE

• To lock other devices externally to the AG-HPX300P, as the

master device, make sure that the other devices are in the
same camera mode as the AG-HPX300P. Note that if some of
the connected devices use interlaced scanning while other
devices use progressive scanning, there may be breaks in the
video and time code.

• When 24P, 24PA or 24PN (native) is selected and the time

code is externally locked, be sure to select a non-drop frame
time code. The time code cannot be externally locked when
drop frame mode is selected. When the time code is externally
locked, the video may be distorted, but this is because of
adjustment to 5-frame segments and not a malfunction.

Outputting the time code externally

To output time code from the camera’s TC OUT connector
to a VTR or other recording device in sync with camera
picture or playback picture, set the setting menu TC VIDEO
SYNCRO (OUTPUT SEL) to VIDEO OUT.
Set the menu option GL SELECT to SDI or COMPOSITE
as required by supplied video output in the OTHER
FUNCTIONS screen and the menu option TC OUT to TCG/
TCR in the OUTPUT SEL screen.

TC OUT

VIDEO IN

SDI IN

HD SDI IN

TC IN

AG-HPX00P

VTR,etc.

SDIOUT

or

VIDEOOUT

NOTE

When the setting menu TC VIDEO SYNCRO is set to VIDEO
OUT, the time code is output via TC OUT in tune with VIDEO
OUT delay.