4 when the display is put in a box – Pioneer PDP 427CMX User Manual

Page 62

Advertising
background image

62

[427CMX]

Special installation (When the display is put in a box)

3.6.4 When the display is put in a box

Operating this display in confined spaces is not recommended.

• If the display is to be used in a confined space, observe the following conditions shown in the drawing below:

A

≥ 50

B

≥ 50

C

≥ 10

D

≥ 50

Use a mesh with aperture efficiency of 50 % or more.

If hot air remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the

inner wall should have sufficient heat resistance or fire resistance.

Usage temperature conditions (BOX air temperature)

• Ambient temperature: 0 °C to 35 °C

Rear view (the following area should be made of mesh)

A

≥ 50

B

≥ 50

C

≥ 10

D

≥ 50

A+

50 mm

A+

50 mm

A+

50 mm

B+

50 mm

B+

30 mm

100 mm

or more

100 mm

or more

Mesh with aperture efficiency
of 50 % or more

A+

50 mm

800 mm or more

800 mm or more

10 mm

10 mm

A

A

B

B

C

D

Exhaust side

Intake side

Outside air temperature
measuring point

: Thermometer

(temperature measurement point)

Advertising