Pioneer PDP 427CMX User Manual

Page 65

Advertising
background image

65

[427CMX]

610

D

D

A

93.4

52.5

52.5

C

10

1022

21.6

25

B

10

Avoid blocking or
covering this area
on the upper and
lower sides.

Attach so that the fan is on the left
side when viewed from the rear.

Special Installation (Hanging on the wall lengthwise)

3.6.6 Hanging on the wall lengthwise

Carefully read the following imformation before attempting to mount the unit on the wall. Observe the various limitations

specified below.

Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.

Shaded areas

indicate attachment points for mounting hardware.

Operating Temperature Restrictions

(*1, *2)

Distance from wall (A)

B

C

D

Ambient temperature

50 mm or more

100 mm or more

50 mm or more

50 mm or more

0 °C to 35 °C

: Thermometer (temperature measurement point)

*1

For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator
Mode 14) Cooling Fan Control Setting” (pg. 235).

*2

When INPUT2 has been selected, use input compatible signal up to 1280x1024 (60 Hz) at ambient temperature
condition of 0 °C to 35 °C.

Advertising